CVE-2026-109439 LANTRONIX · XPress-DR

9.8 Critical

AI summary

Lantronix XPress-DR and XPress-DR-I firmware through 8.1.0.0 exposes an unauthenticated UDP configuration protocol on port 30718, letting remote attackers read and persistently overwrite device configuration such as the IP address and serial forwarding settings. The series reached end-of-support in February 2025; critical (CVSS 9.8), so isolate or replace affected devices.

Official description

Lantronix XPress-DR and XPress-DR-I (CoBos-family) firmware through 8.1.0.0 contains a missing authentication vulnerability that allows remote attackers to read and persistently overwrite device configuration by sending crafted frames to the unauthenticated UDP configuration protocol on port 30718. Attackers can send a type 0xF8 query to read live configuration data and a type 0xFD frame with exactly 0x78 body bytes to rewrite the device IP address and serial-channel forwarding records, causing changes to commit to EEPROM and persist across reboots. The XPress-DR product series reached end-of-life/end-of-support in February 2025.

Published
2026-10-14 17:18 UTC
Modified
2026-10-16 19:00 UTC
CVSS
9.8 Critical CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
EPSS
0.77% (percentile 52)
ENISA EUVD
EUVD-2026-101337
CISA SSVC
Exploitation: none · Automatable: yes · Technical impact: total
CWE
CWE-306

CVSS vector

Attack vector
network
Attack complexity
low
Privileges required
none
User interaction
none
Scope
unchanged
Confidentiality
high
Integrity
high
Availability
high