sadrobot

← Back to the monthly list · Edimax →

CVE-2026-108914 Edimax · BR-6208AC

9.9 Critical

AI summary

Edimax BR-6208AC 1.32 has a buffer overflow via the ifname argument of /goform/formWlSiteSurvey, exploitable remotely with low privileges. A public exploit exists and the product is no longer supported, so no fix is expected. Critical (CVSS 9.9); replacing the device is advised.

Official description

A flaw has been found in Edimax BR-6208AC 1.32. Affected by this issue is some unknown functionality of the file /goform/formWlSiteSurvey. This manipulation of the argument ifname causes buffer overflow. Remote exploitation of the attack is possible. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way. This vulnerability only affects products that are no longer supported by the maintainer.

Published
2026-10-12 17:17 UTC
Modified
2026-10-15 14:17 UTC
CVSS
9.9 Critical CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
EPSS
0.80% (percentile 54)
ENISA EUVD
EUVD-2026-97574
CISA SSVC
Exploitation: poc · Automatable: no · Technical impact: total
CWE
CWE-119

CVSS vector

Attack vector
network
Attack complexity
low
Privileges required
low
User interaction
none
Scope
changed
Confidentiality
high
Integrity
high
Availability
high