← Back to the monthly list · Edimax →
CVE-2026-108914 Edimax · BR-6208AC
AI summary
Edimax BR-6208AC 1.32 has a buffer overflow via the ifname argument of /goform/formWlSiteSurvey, exploitable remotely with low privileges. A public exploit exists and the product is no longer supported, so no fix is expected. Critical (CVSS 9.9); replacing the device is advised.
Official description
A flaw has been found in Edimax BR-6208AC 1.32. Affected by this issue is some unknown functionality of the file /goform/formWlSiteSurvey. This manipulation of the argument ifname causes buffer overflow. Remote exploitation of the attack is possible. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way. This vulnerability only affects products that are no longer supported by the maintainer.
- Published
- 2026-10-12 17:17 UTC
- Modified
- 2026-10-15 14:17 UTC
- CVSS
- 9.9 Critical
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H - EPSS
- 0.80% (percentile 54)
- ENISA EUVD
- EUVD-2026-97574
- CISA SSVC
- Exploitation: poc · Automatable: no · Technical impact: total
- CWE
- CWE-119
CVSS vector
- Attack vector
- network
- Attack complexity
- low
- Privileges required
- low
- User interaction
- none
- Scope
- changed
- Confidentiality
- high
- Integrity
- high
- Availability
- high