sadrobot

← Vissza a havi listához · Apache Software Foundation →

CVE-2026-111496 Apache Software Foundation · Apache Kafka

9.1 Kritikus

MI-összefoglaló

Az Apache Kafka Streams punktuáció-ütemezésében egész túlcsordulás van: egy Long.MAX_VALUE közeli időbélyegű rekord végtelen ciklusba ejti a StreamThread-et, ami újraindítás után is megmarad. A kihasználáshoz írási jog kell egy stream-time punktuációt használó forrás topichoz, és olyan broker, amely elfogadja az ilyen időbélyeget (régebbi brokerek vagy lazított log.message.timestamp.after.max.ms). Frissítsen Kafka Streams 4.2.2, 4.3.2 vagy 4.4.0 verzióra, és korlátozza az írási jogot.

Hivatalos leírás

Kafka Streams derives its stream-time clock from record timestamps. PunctuationSchedule.next() computed the next punctuation time as timestamp + (intervalsMissed + 1) * interval with no overflow check. A record with a timestamp at or near Long.MAX_VALUE advances stream time to that value, so the next stream-time punctuation overflows to a negative time. PunctuationQueue then re-queues that time and loops on it indefinitely while holding a lock, stalling the StreamThread. Impact: A single record is enough. The affected StreamThread stops processing, and because the record stays in the topic the hang returns on restart; an application whose partitions are all affected becomes unresponsive. Only the Streams application is affected, not the brokers or the cluster. Triggering it needs write access to a source topic whose topology uses stream-time punctuation, and a broker that stores the record: brokers from Apache Kafka 4.0.0 reject such a timestamp by default (log.message.timestamp.after.max.ms, one hour), so it is reachable only on older brokers or where that bound has been relaxed. Mitigation: Upgrade Kafka Streams to 4.2.2, 4.3.2, or 4.4.0. As defense in depth, keep log.message.timestamp.after.max.ms bounded on source topics and restrict write access to them. Resolution: From Apache Kafka 4.2.2, 4.3.2, and 4.4.0: the next punctuation time is computed with overflow-checked arithmetic (clamped to Long.MAX_VALUE), and a rescheduled punctuation is re-queued only when its time moves forward.

Megjelent
2026-10-28 17:17 UTC
Módosítva
2026-11-05 20:17 UTC
CVSS
9.1 Kritikus CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H
EPSS
0.54% (percentilis 39)
ENISA EUVD
EUVD-2026-112171
CISA SSVC
Kihasználás: none · Automatizálható: yes · Technikai hatás: partial
CWE
CWE-190

CVSS-vektor

Támadási útvonal
hálózatról
Bonyolultság
alacsony
Szükséges jogosultság
nem kell
Felhasználói közreműködés
nem kell
Hatókör
változatlan
Bizalmasság
magas
Sértetlenség
nincs
Rendelkezésre állás
magas

Hivatkozások